B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
2.15.3

Configuration file NETNAMES.INI, standard functionality

2.15.3.1

Two operator panel fronts and one NCU

A sample configuration file for the second control unit is given below for a system consisting
of two control units and one NCU on the OPI.
; NETNAMES.INI Example 2 Start
; Identification entry
[own]
owner = MMC_2
; Connection entry
[conn MMC_1]
conn_1 NCU_1
[conn MMC_2]
conn_1 NCU_1
; Descriptive entry
[param network]
bus = opi
[param MMC_1]
mmc_address = 1
[param MMC_2]
mmc_address = 3
[param NCU_1]
nck_address = 13
plc_address = 13
; NETNAMES.INI example 2 End
2.15.3.2

One operator panel front and three NCUs

A sample configuration file is given below for a system consisting of one control unit and
three NCUs on the OPI.
Extended Functions
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
2.15 Examples
221