„ SPECIFICATION SUMMARY
Type
Max. System Controller Lite per VRF
Network
Max. VRF networks supported
System specification
Max. indoor units / remote controller groups
per VRF network
Max. indoor units / remote controller groups
per System Controller Lite
Multiple sites display
2D/3D graphical layout view
Site supervision
List display
Tree display
Start/Stop, Operation mode, Room
temperature
Fan speed, Airflow direction
Economy mode
Antifreeze
Individual
Remote control prohibition setting
Temperature upper and lower limit setting
Filter sign reset
Human sensing
Operation
Annual schedule
control
Schedule
Low noise mode weekly schedule
Number of groups
Group in group
Group
management
Max. overlap definitions
Auto generation
Memory operation
Others
Pattern operation
Controlled status
Operation status
monitoring
Special operation
Room Temp.
Room temperature
Error notification
Error management
Audible alarm
Error e-mail notification
Error history
History management
Operation control & status history
Indoor unit rotation
Outdoor unit capacity save
Peak cut control
Energy saving
Power consumption monitor
management
Electricity meters supported
Power consumption information
Apportionment charge calculation
Apportionment charge bill creation
Tenant (block) setting
Common facilities apportionment setting
Rated power consumption allotment setting
Electricity charge
apportionment
Electricity meters supported
Electricity charge apportionment period
Prepaid air conditioning
Cooling and Heating information
Internet, telephone line support
Max. client connection per server
Remote control
Max. host connection from client
Data encryption
UTY-
Function
ALGXZ1
1
1
400
400
10
z
z
z
z
z
z
z
z
z
z
z
z
400
3 Levels
400
z
z
z
z
z
z
z
z
z
1 year
1 year
- (05 - 27) -
UTY-
UTY-
UTY-
UTY-
PLGXA2
PLGXR2
PLGXE2
PLGXP2
Option
Option
Option
Option
z
z
1 month
z
200
3 years
z
z
1600
z
z
200
2 years
z
z
z
5
10
z
UTY-
PLGXX2
Remark
Option
.
Quick control from display available.
Quick control from display available.
Week of year, day of month, day of
week setting.
Holiday special day settings.
Outdoor unit control only.
Lv.1 – 2 – 3.
1 unit may belong to up to 400
groups.
By site, building and floor.
Operation pattern memorized and
reused.
Reuse operation pattern once used.
See items controlled by operation.
Defrost, Oil Recovery.
1
*
Outdoor unit required per
connection
Same meters used for energy
saving.
SSL used.