Example Flow - Fujitsu Airstage J-II Series Design & Technical Manual

Small vrf system
Table of Contents

Advertisement

1-5-4. EXAMPLE FLOW

z Example 1 : To automatically set the addresses of signal amplifiers,
Heat Recovery system
Master unit
1
1
1
Refrigerant system1
Heat Recovery system
Master unit
2
2
2
Signal amplifier
Refrigerant system2
Heat Pump system
2
Master unit
3
3
3
Refrigerant system3
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Step 6:
indoor units and RB units
Follow the step below
3
1
2
12
8
1
1
1
9
2
3
1
4
2
2
2
*2
12
18
1
3
3
3
 Activate the Signal Amplifier Automatic Address Setting function on the master
unit of Refrigerant System 1.
An address is automatically assigned to all signal amplifiers on the network.
(Because an address is also assigned to the signal amplifiers being
connected in Refrigerant Systems 2 and 3, it is not necessary to perform the
automatic address setting of these signal amplifiers again on the master units
of Refrigerant Systems 2 and 3.)
 Activate the Indoor Unit Automatic Address Setting function on the master unit
of Refrigerant System 1.
An indoor unit address and a refrigerant circuit address are automatically set
up for all indoor units being connected in Refrigerant System 1.
 Activate the Indoor Unit Automatic Address Setting function on the master unit
of Refrigerant System 2.
An indoor unit address and a refrigerant circuit address are automatically set
up for all indoor units being connected in Refrigerant System 2.
 Activate the Indoor Unit Automatic Address Setting function on the master unit
of Refrigerant System 3.
An indoor unit address and a refrigerant circuit address are automatically set
up for all indoor units being connected in Refrigerant System 3.
 Activate the RB Unit Automatic Address Setting function on the master unit of
Refrigerant System 1.
A RB unit address and a refrigerant circuit address are automatically set up
for all RB units being connected in Refrigerant System 1.
 Activate the RB Unit Automatic Address Setting function on the master unit of
Refrigerant System 2.
A RB unit address and a refrigerant circuit address are automatically set up
for all RB units being connected in Refrigerant System 2.
Signal amplifier
7
12
1
1
21
4
1
26
1
1
1
1
5
3
2
2
25
6
8
17
2
2
2
2
10
23
4
22
3
3
3
3
- (07 - 52) -
*1
2
1
RB unit address No.
1
Refrigerant circuit address No.
18
3
Indoor unit address No.
1
1
Refrigerant circuit address No.
1
RB unit address No.
2
Refrigerant circuit address No.
11
28
Indoor unit address No.
2
2
Refrigerant circuit address No.
8
9
Indoor unit address No.
3
3
Refrigerant circuit address No.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Airstage aou36rlavmAirstage aou48rlavmAirstage aou60rlavmAirstage auua4tlav1Airstage auua7tlavAirstage auua9tlav ... Show all

Table of Contents