Analog Digital Convert Calibration; Performing A Pc Calibration; Performing A Video Calibration - Christie HS Series Service Manual

Hide thumbs Also See for HS Series:
Table of Contents

Advertisement

Analog digital convert calibration

If the color appears abnormal after upgrading the scalar firmware, perform an analog digital convert
(ADC) calibration.
Warning! If not avoided, the following could result in death or serious injury.
• Do not stare into beam when the projector is on. The bright light may result in permanent eye
damage.

Performing a PC calibration

To perform the PC calibration, complete the steps below.
ID
Part name
1
Test equipment
2
Test signal
3
Test pattern
4
Inspection item
1. On the IR remote keypad, press Menu and select Size & Position > Size Presets > Full
Size.
2. Enter Factory mode.
See
Entering Factory mode
3. Select ADC Calibration > Help.
After a few seconds, the ADC calibration status changes from Doing to Done.

Performing a video calibration

To perform the video calibration, complete the steps below.
ID
Part name
1
Test equipment
HS Series D13 Service Manual
020-000892-03 Rev. 1 (12-2019)
Description
Video generator (output level: 700 mv)
Timing: 800 x 600 @60Hz
16 Gray
Check if the ADC calibration status has changed from Doing to Done.
on page 19.
Description
Video generator (output level: 700 mv)
Service setups
24