Qualstar XLS Series Technical & Service Manual page 64

Tape libraries
Hide thumbs Also See for XLS Series:
Table of Contents

Advertisement

4.3 Inspecting the Cartridge Slots and Fiducials
To inspect or clean the library's interior, follow these steps:
1.
Shut down the library (see
2.
Open the door(s).
3.
As needed, use a vacuum cleaner or slightly damp cloth to dust the inside of the
cabinet.
4.
Inspect each cartridge magazine and the fiducial targets on each side of the
magazine. If you notice broken or worn parts, replace the magazine. See
Section 9.2 on page
5.
Replace any cleaning cartridges in the system-reserved slots (G46 to G49). See
Figure
Important:
Figure 4-7 Location of the calibration and reserved cleaning cartridges
6.
Inspect the calibration cartridge in the system-reserved slot (G50) and replace it
if it is worn or damaged. See
7.
Close the door(s) and restart the library.
4-6
Section 6.2 on page
9-2.
4-7.
Be sure that the system-reserved slots contain cleaning
cartridges only. Never install data cartridges in these
slots.
Figure
6-1).
Calibration
cartridge slot
(G50)
Cleaning
cartridge slots
(G46-G49)
4-7.
501610 Rev. 07-01-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xls-832700Xls-820500Xls-812300

Table of Contents