Table 104. Touch Probe Functions; Table 105. Touch Probe Status - Parker P Series User Manual

New servo system
Hide thumbs Also See for P Series:
Table of Contents

Advertisement

9
10
11
12
13
14 to 15

Table 104. Touch Probe Functions

0x60B9
Variabl
e
Format
UINT
Show touch probe status.
Bit
0
1
2
3 to 5
6
7
8
9
10
11 to 13
14
15

Table 105. Touch Probe Status

Parker Hannifin
1
Use touch probe 2
0
Single trigger mode
1
Continuous trigger mode
0
Trigger by touch probe 2 input
1
Trigger by index pulse signal
Reserved
0
Do not capture positive edge position value of touch probe 2
1
Capture positive edge position value of touch probe 2
Do not capture negative edge position value of touch probe 2
0
Capture negative edge position value of touch probe 2
1
Reserved
Default
Setting Range
Value
-
Value
Do not use touch probe 1
0
Use touch probe 1
1
0
Positive edge position value of touch probe 1 is not stored
1
Positive edge position value of touch probe 1 is stored
0
Negative edge position value of touch probe 1 is not stored
1
Negative edge position value of touch probe 1 is stored
Reserved
Toggled when positive edge position value of touch probe 1 is
0, 1
updated
Toggled when negative edge position value of touch probe 1 is
0, 1
updated
Do not use touch probe 2
0
Use touch probe 2
1
0
Positive edge position value of touch probe 2 is not stored
1
Positive edge position value of touch probe 2 is stored
0
Negative edge position value of touch probe 2 is not stored
1
Negative edge position value of touch probe 2 is stored
Reserved
Toggled when positive edge position value of touch probe 2 is
0, 1
updated
Toggled when negative edge position value of touch probe 2 is
0, 1
updated
Touch Probe Status
Acces
Unit
sibility
-
-
RO
Descriptions
PDO
Change
Allocati
Property
on
Yes
-
P series User Guide
ALL
Stor
e
No
249

Hide quick links:

Advertisement

Table of Contents
loading