Figure 50. Touch Probe Function Timing Diagram - Parker P Series User Manual

New servo system
Hide thumbs Also See for P Series:
Table of Contents

Advertisement

0x60B8.0
(0x60B8.8)
0x60B8.4
(0x60B8.12)
0x60B9.0
(0x60B9.8)
0x60B9.1
(0x60B9.9)
0x60BA
(0x60BC)
0x60B9.6
(0x60B9.14)
Probe input
0x60B8.0
(0x60B8.8)
0x60B8.1
(0x60B8.9)
0x60B8.2
(0x60B8.10)
0x60BA
(0x60BC)
0x60B9.6
(0x60B9.14)
Index(Z) Pulse

Figure 50. Touch Probe Function Timing Diagram

Parker Hannifin
Latch start
Position 1 Latched
1
Index Pulse Trigger Mode (0x60B8.2=1, 0x60B8.10=1):
Single Trigger mode
Position 1
Latched
1
2
3
Position 2 Latched
2
Continuous Trigger mode
Position 5
Position 6
Latched
Latched
4
5
6
Position 3 Latched
3
Position 7
Position 8
Position 9
Latched
Latched
Latched
7
8
9