Table 57. Allocating Digital Output Related Objects - Parker P Series User Manual

New servo system
Hide thumbs Also See for P Series:
Table of Contents

Advertisement

0x2216
-
0x2217
-

Table 57. Allocating Digital Output Related Objects

You can set the output signal level by allocating functions of digital output signals of I/O
connector. Choose the signals to allocate with bit 7~0, and set the signal level at bit 15.
Set
Allocatable Output
Value
Signals
0x00
Not Allocated
0x01
BRAKE
0x02
ALARM
0x03
RDY
0x04
ZSPD
0x05
INPOS1
0x06
TLMT
0x07
VLMT
0x08
INSPD
0x09
WARN
0x0A
TGON
0x0B
INPOS2
0x10
ORG
0x11
EOS
0x12
IOUT0
0x13
IOUT1
0x14
IOUT2
0x15
IOUT3
0x16
IOUT4
0x17
IOUT5
Parker Hannifin
Digital Output Signal 4
Selection
Digital Output Signal 4
Selection
Bit
15
14~8
7~0
UINT
RW
UINT
RW
Details
Signal output level setting
(0:CONTACT A, 1:CONTACT B)
Reserved
Allocated output signal
P series User Guide
-
-