The main power is ON
No alarm
Servo is OFF
Operation speed is set considering the condition of the machine
Related Objects
Sub
Index
Index
0x230C
Table 88. Index Pulse Probing Related Objects
7.1.6 Absolute Encoder Reset
Absolute encoder reset is needed in the following cases.
Setting up the mechanical unit for the first time
Encoder low voltage occurs
The multi-turn data of absolute encoder needs to be 0
Resetting the absolute encoder resets multi-turn data(0x260A) and single-turn data(0x2607)
back to 0. Re supplying power after reset changes the position actual value (0x6064) to the
reset position value.
After power resupply, the position actual value (0x6064) of the absolute encoder is read and
displayed by applying Home offset(0x607C).
Changing the home offset (0x607C) during operation will not change the position actual
value (0x6064).
Related Objects
Index
Index
0x2005
0x2607
Parker Hannifin
Name
-
Index Pulse Search Speed
Sub
Name
-
Absolute Encoder Configuration
Single Turn Data
Variable
Accessibility
Format
INT
RW
Variable
Format Accessibility
UINT
RW
UDINT
RO
P series User Guide
PDO
Unit
Allocation
No
rpm
PDO
Allocation Unit
No
-
Yes
pulse
155