Example of Digital Output Allocation
The table below shows an example of allocating input signals. Please note the set
values of 0x2210~0x2217.
DO#1
DO#2
ALARM
RDY
(CONTACT
(CONTACT
B)
A)
CN1
Pin number
DO # 1 (35,36)
DO # 2 (37,38)
DO # 3 (39,40)
DO # 4 (41,42)
DO # 5 (43,44)
DO # 6 (45,46)
DO # 7 (47,48)
DO # 8 (49,50)

Table 58. Example of Signal Output Allocation

4.5.3 Using User I/O

User I/O refers to a portion of I/S provided by the drive used for user's purposes
other than the purpose of controlling the drive. All contacts provided through I/O
connector can be used as User I/O.
If the number of User I/O required is small, you can use the drive's I/O connector
instead of using additional I/O modules, resulting in cost reduction.
This drive provides up to 16 input signals and 8 output signals as user I/O.
Parker Hannifin
DO#3
DO#4
BRAKE
INPOS1
(CONTACT
(CONTACT
B)
A)
Set
Bit
Parameter
15
0x2210
1
0x2211
0
0x2212
1
0x2213
0
0x2214
0
0x2215
0
0x2216
0
0x2217
0
DO#5
ORG
(CONTACT
(CONTACT
A)
Set value
7~0
0x02
0x8002
0x03
0x0003
0x01
0x8001
0x05
0x0005
0x10
0x0010
0x11
0x0011
0x0A
0x000A
0x06
0x0006
DO#6
DO#7
EOS
TGON
(CONTACT
A)
A)
Content
ALARM (Contact B)
RDY (Contact A)
BRAKE (Contact B)
INPOS1 (Contact A)
ORG (Contact A)
EOS (Contact A)
TGON (Contact A)
TLMT (Contact A)
P series User Guide
DO#8
TLMT
(CONTACT
A)
92