1
8
OUT
Pin arrangement viewed from the front
side of the drive
Pin No.
1
2
3
4
Table 20. RS-422 Connector Pin Description
NOTE ) As for IN connector, 5V voltage is output to Pin No. 7 and Pin No. 8, to supply
power to the handy loader. Use for any other purpose is not allowed, and do not
connect Pin No. 7 and Pin No. 8 when wiring.
NOTE ) Connect TXD+ and TXD-, RXD+ and RXD- using twisted pair.
NOTE ) TXD and RXD of the above table is defined based on the servo drive.
4.2.3 Packet Structure
Maximum length of transmission/reception packet of MODBUS-RTU is 256 Byte.
Please make sure the total length of transmission/reception packet does not exceed
256 byte.
To classify packets, MODBUS-RTU Communication Mode requires empty spaces of at
least 3.5 characters at the starting point and the end point.
to
at least 3.5 char
Transmission Packet Structure
Additional
Address
Byte
description
Node ID
Table 21. RS-422 Transmission Packet Structure
Parker Hannifin
1
IN
Pin Function
Not Used
Not Used
RXD+
TXD-
Packet1
at least 3.5 char
Functio
n Code
0
1
Function
Data
8
Pin arrangement viewed from the
Pin No.
5
6
7
8
Packet2
4.5 char
Data
2
.
.
.
.
connector
Pin Function
TXD+
RXD-
Not Used
Not Used
Packet3
Error Check
n-1
n
CRC(MSB)
CRC(LSB)
P series User Guide
64