Allocating Digital Output Signals; Table 56. Example Of Signal Input Allocation - Parker P Series User Manual

New servo system
Hide thumbs Also See for P Series:
Table of Contents

Advertisement

Example of Input Signal Allocation
The table below shows an example of allocating input signals. Please note the set
values of 0x2200~0x220F.
DI1
DI2
SV_ON
POT
(CONTA
(CONTAC
CT A)
T A)
DI 9
DI 10
HOME
HSTART
(CONTA
(CONTAC
CT B)
T B)
CN1
(Pin number)
DI # 1 (12)
DI # 2 (13)
DI # 3 (14)
DI # 4 (15)
DI # 5 (16)
DI # 6 (17)
DI # 7 (18)
DI # 8 (19)
DI # 9 (22)
DI # A (23)
DI # B (24)
DI # C (25)
DI # D (26)
DI # E (27)
DI # F (28)
DI # 10 (29)

Table 56. Example of Signal Input Allocation

4.5.2 Allocating Digital Output Signals

You can set the functions of digital output signal of I/O connector and output signal
level. Among the 19 output functions listed below, you can allocate the functions
that you want to use to digital input signals 1 through 8 at your discretion.
Parker Hannifin
DI3
NOT
A-RST
(CONTAC
(CONTAC
T A)
DI 11
DI 12
ISEL1
ISEL0
(CONTAC
(CONTAC
T A)
Bit
Set
15
7~0
parameter
0x2200
0
0x0F
0x2201
0
0x01
0x2202
0
0x02
0x2203
0
0x0C
0x2204
0
0x10
0x2205
0
0x04
0x2206
0
0x12
0x2207
0
0x0B
0x2208
1
0x03
0x2209
1
0x13
0x220A
0
0x14
0x220B
0
0x15
0x220C
0
0x16
0x220D
0
0x17
0x220E
0
0x18
0x220F
0
0x19
DI4
DI 5
START
(CONTAC
(CONTAC
T A)
T A)
DI 13
ISEL2
(CONTAC
(CONTAC
T A)
T A)
Set
Content
value
0x000F
SV_ON(A CP)
0x0001
POT(A CP)
0x0002
NOT(A
0x000C
A-RST(A
0x0010
START(A
0x0004
STOP(A
0x0012
REGT(A CP)
0x000B
EMG(A
0x8003
HOME(B CP)
0x8013
HSTART(B CP)
0x0014
ISELO(A CP)
0x0015
ISEL1(A CP)
0x0016
ISEL2(A CP)
0x0017
ISEL3(A CP)
0x0018
ISEL4(A CP)
0x0019
ISEL5(A CP)
DI 6
DI 7
STOP
REGT
(CONTAC
T A)
T A)
DI 14
DI 15
ISEL3
ISEL4
(CONTAC
T A)
T A)
)
CP
)
CP
)
CP
)
CP
)
CP
P series User Guide
DI 8
EMG
(CONTAC
T A)
DI 16
ISEL5
(CONTAC
T A)
89

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents