Figure 15. System Installation Overview
Warning
This product has been developed for industrial environments. Due to exposed high
voltage terminals, this product must not be accessible to users while under normal
operation.
3.3 Power Supply
3.3.1 Power Circuit Electronics Specification
Type
100W
MCCB
Noise Filter
(NF)
DC Reactor
MC
Power Cable
Pressure
Terminal
Recovery
Resistance
(default)
Table 11. Power Circuit Electronics Specification
Parker Hannifin
200W
400W
ABS33bM(8A)
RFY-4010M
HFN-6(6A)
GMC-9(11A)
AWG16
(1.25 SQ)
UA-F1510, SEOIL
(10mm Strip & Twist)
50[W]
100Ω
800W
1kW
12A
HFN-10(10A)
GMC-18(18A)
AWG14
(2.0 SQ)
UA-F2010, SEOIL
(10mm Strip & Twist)
100[W]
40Ω
P series User Guide
2kW
3.5kW
24A
4020M
4030M
HFN-30(30A)
GMC-40(35A)
AWG12
(4.0 SQ)
UA-F4010, SEOIL
(10mm Strip & Twist)
150[W]
13Ω