Wiring; Power; Figure 18. Drive Wiring Example - Parker P Series User Manual

New servo system
Hide thumbs Also See for P Series:
Table of Contents

Advertisement

3.11 Wiring

3.11.1 Power

Figure 18. Drive Wiring Example

Note 1) Please press the ON switch for the main power for at least 2 seconds, as the
alarm signal input takes 1~2 seconds after the main power is turned on.
Note 2) 100[W]~400[W]drive has built-in recovery resistance of 50[W], 100[Ω],
800[W]~1[kW]drive has 100[W], 40[Ω]; and 2[kW]~ 3.5[kW]drive has 150[W],
13[Ω] recovery resistance. Please use them by shorting terminals B and BI. If
the recovery resistance is high due to frequent acceleration/deceleration, please
open the shorting pins (B, BI) and connect external recovery resistance to B, B+.
Note 3) Please peel off the 7~10[mm] of the sheath of the power cable to be used for the
power unit as shown in the figure below. And use the dedicated pressure
terminal (see ― 3.3.1 Power Circuit Electronics Specifications ‖)
Note 4) When removing power unit wiring from 100[W]~1[kW] drive, remove or connect
it after pressing the button at the drive's terminal block. In case of 2[kW]~3.5[kW]
drive, remove or connect it using a flat-head driver.
Please check the voltage of the input power so that it does not exceed the
permissible window.
Connecting commercial power with the drive's U, V, W terminals may cause
damage. Please connect the power to the L1, L2, L3 terminals.
Parker Hannifin
P series User Guide
50