When the output frequency of the host device and the drive's input
frequency are restricted when driving a high-resolution encoder at a high
speed
-
A regular high-speed line drive pulse output unit has output frequency of around
500Kpps. The drive's input frequency is around 1~4Mpps. For this reason, driving a
high-resolution encoder at a high speed restricts the output frequency of the host device
and the drive's input frequency. Electronic gears must be used to achieve normal driving.

6.5.2 Example of Electronic Gear Setting

Ball Screw Load
Unit Specifications
User Unit
Encoder Specifications
Load Movement / 1
revolution
Electronic Gear setting
Turntable Load
Unit Specifications
User Unit
Encoder Specifications
Load Movement / 1
revolution
Electronic Gear setting
Parker Hannifin
Pitch: 10mm, Deceleration ratio:1/1
1um(0.001mm)
19bit(524288 PPR)
10[mm] = 10000[User Unit]
Motor Revolutions : 524288
Shaft Revolutions : 10000
Deceleration ratio:100/1
19bit(524288 PPR)
360/100/0.001=3600
Motor Revolutions : 524288
Shaft Revolutions : 3600
0.001°