Dip Switch Configuration Settings; Performance Test Initiation; Dip Switch Test; Feed Motor Forward Rotation Test - JCM GLOBAL VEGA Series Operation And Maintenance Manual

Table of Contents

Advertisement

Calibration and Testing
3. Turn the VEGA Unit Power
mance Test Mode will activate.
NOTE: When the VEGA
Performance Test Mode begins, the
Front Panel LED slowly flashes at a
Green
Color rate.

DIP Switch Configuration Settings

Table 6-2 lists the various Performance Test DIP Switch Setting configurations for each test type.
Table 6-2 Performance Test DIP Switch Configuration Settings
Test Type

DIP Switch Test

Feed Motor Normal Rotation Test

Feed Motor Reverse Rotation Test

Stacker Motor Test
Aging Test
Off-line Banknote Acceptance Test
Sensor Test
Standby Color Indication
(Rainbow Gradient)
Standby Color Indication (Green)
Standby Color Indication (Blue)
ccTalk Encryption Code Initialization
*. See "LED Pattern Setting Mode" on page 2-3 for making "Rainbow" setting (Gradation).
†. See "LED Pattern Setting Mode" on page 2-3 for making GREEN setting (Green).
‡. See "LED Pattern Setting Mode" on page 2-3 for making BLUE setting (Blue).
**. See "Rewriting ccTalk Encryption Code (Initialize)" on page 2-3 for making the communication Protocol setting.

Performance Test Initiation

Set the various DIP Switches listed in Table 6-2 for
each test AFTER the Performance Test Mode is
activated. Once the DIP Switches on both DS1 and
DS2 have been set for the desired Test; set DIP
Switch DS1, Switch #1 to
stop the current Test and return to the Standby
Mode, reset DIP Switch DS1 #1 to
NOTE: After performing an "Off-line"
Banknote Acceptance Test, cycle the
VEGA Unit's power OFF/ON to return to
the Standby Mode. Unless the power is
turned OFF/ON, the next test WILL NOT
run.
The following information describes each test in
detail.
DIP S
T
WITCH
EST
Perform the following steps to test the functionality
of each DIP Switch Block:
1. Ensure that the VEGA Unit power is
2. Set all Switches on DIP Switch DS1 and DS2 to
ON
as indicated in Table 6-2 for this Test.
3. Turn the VEGA Unit power
P/N 960-100189R_Rev. 4 {EDP #148850}
VEGA™ Series Banknote Validator
ON
, and the Perfor-
DIP Switch Block 1 Switch#
1
2
3
4
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
ON OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
ON ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
ON ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF
*
ON OFF ON OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF
ON OFF OFF ON OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF
**
ON ON ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
OFF
to begin the test. To
ON
.
OFF
.
ON
.
DIP Switch Block 2 Switch#
5
6
7
8
1
4. Set DIP Switch DS1 #1 to ON to begin the test.
Confirm that the Front Panel LED will extin-
guish.
5. Set the ODD numbered DIP Switches (i.e., DIP
Switch DS1 and DS2 Switches #1, #3, #5 and #7)
OFF
to
. The Front Panel LED flashes at a
Color rate.
6. Set the EVEN numbered DIP Switches (i.e., DIP
Switch DS1 and DS2 Switches #2, #4, #6 and #8)
OFF
to
. The Front Panel LED flashes at a
Color rate if all of the DIP Switches function cor-
rectly.
NOTE: If the DIP Switches were set
incorrectly during the test, the Front
Panel LED flashes Red, indicating a
Test failure. However, if the DIP
Switches were set correctly, and the
LED still flashes Red, then a DIP
Switch failure is indicated.
F
M
F
EED
OTOR
ORWARD
Perform the following steps to test the normal for-
ward rotation functionality of the Feed Motor:
1. Ensure that the VEGA Unit power is
© 2016, JAPAN CASH MACHINE CO., LTD.
6 - 1 7
2
3
4
5
6
7
Yellow
Blue
R
T
OTATION
EST
OFF
.
Section 6
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents