Advertisement

ETH-PT (Control LAN Ethernet)
Table 8-295. Test #1286 Session Status Test
Error
Test
Code
Result
Description / Recommendation
1124
ABORT
Ethernet link is not enabled.
1125
ABORT
Ethernet link not in service.
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
2100
ABORT
Could not locate the necessary system resources to run this test.
2500
ABORT
Internal system error.
1
FAIL
System software indicates at least one Ethernet link session is down (SOME
UP).
555-233-143
1. Verify that the Ethernet link is enabled (status port UUCSSpp, status
link n, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1. Verify whether Ethernet link is in service (status port UUCSSpp or
status link n).
2. If the Ethernet link is not in service, release the link (release link n or
release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
1. If the problem persists, reset the circuit pack (busyout board
UUCSSpp, reset board UUCSS, and release board UUCSS).
2. If the problem persists, replace the circuit pack.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1. Isolate downed sessions (status port UUCSSpp or status link n).
2. Follow actions based on session information.
Continued on next page
Issue 1 May 2002
8-753