Maintenance-Object Repair Procedures
Table 8-328. Test #759 Configuration Audit — Continued
Error
Test
Code
Result
Description / Recommendation
113
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped SNI
in slot 13. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 2049, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 2049, replace the
114
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped SNI
in slot 14. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 2305, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 2305, replace the
115
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped SNI
in slot 15. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 2561, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 2561, replace the
8-848
Issue 1 May 2002
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 13.
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 14.
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 15.
4-19. This should
4-19. This should
4-19. This should
Continued on next page
555-233-143