ABB i-bus
KNX
Group objects
8.7

Group objects Inputs

No.
52
This group object is enabled if the parameter Monitor receipt of group object "Operating mode" is set to Acti-
vated in the Monitoring and safety parameter window.
This group object changes to the value 1 if the parametrized monitoring time was exceeded without the
group object being received.
The status changes back to 0 when the group object is received again.
The group object is sent on each state change (0 > 1 or 1 > 0).
53
This group object is enabled if the parameter Input is set to Temperature sensor in the Input a parameter
window.
This group object sends the temperature value measured at the input on the bus depending on the reaction
parametrized in the parameter Send temperature value.
54
This group object is enabled if the parameter Input is set to Temperature sensor in the Input a parameter
window.
This group object is also enabled if the parameter Connect analog room control unit to physical device input
a is set to Yes in the Setpoint adjustment parameter window.
This group object changes its status to 1 if a fault (idling or short circuit) is found at the input and it is there-
fore no longer possible to send measured values.
If there is not fault at the input, this group object value is 0.
55
This group object is enabled if the parameter Input is set to Binary signal input in the Input a parameter win-
dow.
Depending on the selected parametrization, this group object indicates the contact position of the binary sen-
sor connected to the input.
55
This group object is enabled if the parameter Input is set to Window contact in the Input a parameter window.
Depending on the selected parametrization, this group object indicates the state of the window contact con-
nected to the input.
55
This group object is enabled if the parameter Input is set to Dew point sensor in the Input a parameter win-
dow.
Depending on the selected parametrization, this group object indicates the state of the dew point sensor con-
nected to the input.
55
This group object is enabled if the parameter Input is set to Fill level sensor in the Input a parameter window.
Depending on the selected parametrization, this group object indicates the state of the fill level sensor con-
nected to the input.
Function
Error: operating mode receipt
Temperature
Input error
Switch
Window contact
Dew point alarm
Fill level alarm
Group object name Data Type
Channel – General
1 bit
DPT 1.002
Channel – Input a
2 bytes
DPT 9.001
Channel – Input a
1 bit
DPT 1.002
Channel – Input a
1 bit
DPT 1.001
Channel – Input a
1 bit
DPT 1.005
Channel – Input a
1 bit
DPT 1.005
Channel – Input a
1 bit
DPT 1.005
FCC/S 1.X.X.1 | 2CDC 508 200 D0211 Rev A 333
Flag
C, R, T
C, R, T
C, R, T
C, R, T
C, R, T
C, R, T
C, R, T