AH M o ti on Co n tro l ler – Op era tion Ma nua l
Function Block—DFB_CamCurveUpdate2
After DFB_CamCurve2 is executed, DFB_CamCurveUpdate2 can be used. If you want to modify a rotary cut curve, you
can create a new rotary cut curve by DFB_CamCurve2, and then update the rotary cut curve by DFB_CamCurveUpdate2.
Inputs
Name
Execute
Outputs
Name
Done
Busy
Error
ErrorID
_7
7 - 5 0
Function
Executes the instruction to update the
cam profile.
Function
True when the cam curve is established.
True when the instruction is executed.
True if an error occurs.
Indicates the error code if an error occurs.
Refer to Appendices for error code
descriptions.
Setting value
Data type
(Default value)
True/False
BOOL
(False)
Data type
Output range (Default value)
BOOL
True/False (False)
BOOL
True/False (False)
BOOL
True/False (False)
DWORD
0x0000, 0x3100, 0x3101, 0x3102 (0)
Timing for updating
-