SR (Special Relay) Area
Word(s)
Bit(s)
274
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
00
275
01
02
03
04
05
06 to 07
08 to 15
276
00 to 07
08 to 15
277 to 279
00 to 15
280
00 to 15
281
00 to 15
282
00 to 15
283 to 286
00 to 15
287 to 288
00 to 15
289
00 to 07
08
09 to 10
11
12
13 to 14
15
290 to 293
00 to 15
294 to 297
00 to 15
298 to 299
00 to 15
Special I/O Unit #0 Restart Flag
Special I/O Unit #1 Restart Flag
Special I/O Unit #2 Restart Flag
Special I/O Unit #3 Restart Flag
Special I/O Unit #4 Restart Flag
Special I/O Unit #5 Restart Flag
Special I/O Unit #6 Restart Flag
Special I/O Unit #7 Restart Flag
Special I/O Unit #8 Restart Flag
Special I/O Unit #9 Restart Flag
Special I/O Unit #A Restart Flag
Special I/O Unit #B Restart Flag
Special I/O Unit #C Restart Flag
Special I/O Unit #D Restart Flag
Special I/O Unit #E Restart Flag
Special I/O Unit #F Restart Flag
PC Setup Error (DM 6600 to DM 6605)
PC Setup Error (DM 6613 to DM 6623)
PC Setup Error (DM 6645 to DM 6655)
Reserved by system (not accessible by user)
Changing RS-232C Setup Flag
Reserved by system (not accessible by user)
Reserved by system (not accessible by user)
Reserved by system (not accessible by user)
Minutes (00 to 59)
Hours (00 to 23)
Used for keyboard mapping. See page 416.
Group-2 High-density I/O Unit Error Flags for Units 0 to F
(AR 0205 to AR 0214 also function as Error Flags for Units 0 to 9.)
Special I/O Unit Restart Bits for Units 0 to F
(Units 0 to 9 can also be restarted with Special I/O Unit Restart Bits AR 0100 to AR 0109.)
• To restart a Special I/O Unit, either use for force-set/reset operation to turn the Restart Bit ON
and OFF, or turn OFF the power and then turn it ON again.
• Follow the same procedure as above for starting PC Link Units.
Special I/O Unit Error Flags for Units 0 to F
(AR 0000 to AR 0009 also function as Error Flags for Units 0 to 9.)
Communications Board monitoring area
Communications Board interrupt data area
Communications Board general monitoring area
Communications Board Port A Instruction Execution Flag
Used by Communications Board Port A instructions
Communications Board Port A Instruction Abort Bit
Communications Board Port B Instruction Execution Flag
Used by Communications Board Port B instructions
Communications Board Port B Instruction Abort Bit
Macro Area inputs.
Macro Area outputs.
Reserved by system (not accessible by user)
Function
These flags will turn ON during restart processing.
g
These flags will not turn ON for Units on Slave
Th
fl
ill
ON f
Racks.
Racks
Indicates the current time in BCD.
Section 3-4
g
p
g
U i
Sl
37