C200HX/HG/HE Features
Function
Function
CPU Unit
RS-232C port
functions
Clock function
SYSMAC NET Link and
SYSMAC LINK functions
Communications
---
Boards
Special I/O Units ---
Interrupts
p
Interrupt Input Units
Communications Board
interrupts
Response characteristics
PTs
---
SYSMAC LINK
Service time
Remote programming
Effect on response time
1-8-2 Program Compatibility
Precautions
8
C200HX/HG/HE
Available in the
C200HX/HG/HE-CPU4j-E/6j-E
Available in all except the C200HE-CPU11-E
Communications Boards can be installed in
all PCs except the C200HE-CPU11-E.
(Board model numbers:
C200HW-COM01/04-E)
Communications Boards can be installed in
all PCs except the C200HE-CPU11-E. These
Boards can provide the following functions:
SYSMAC NET Link and SYSMAC LINK,
Communications Ports (Ports 1 and 2), and
Protocol Macro functions
The IORD(––) and IOWR(––) instructions
allow data to be transferred to and from
Special I/O Units.
2 Units (16 inputs)
Can be set.
Same as the C200HS, although a 1-ms
response is possible in the C200HW-SLKjj
NT Link (1:1) or NT Link (1:N)
(Up to 8 PTs can be connected from the
RS-232C port through an RS-422/485 Link
Adapter. When the C200HE-CPUjj-E with
a Communications Board is used, only 3 PTs
can be connected)
3.5 ms max. (1 operating level)
Possible from the Peripheral Port or RS-232C
Ports (including Communications Boards).
None
C200HS programs and Memory Cassettes can be used as is in the C200HX/
HG/HE and programs developed for the C200H can be transferred for use in the
C200HX/HG/HE very easily.
Detailed procedures for the individual steps involved in transferring programs
can be found in the SSS Operation Manuals. You will also require a
CQM1-CIF02 Connecting Cable to connect the computer running SSS to the
C200HS.
Observe the following precautions when transferring C200H programs to the
C200HX/HG/HE.
• If a C200H program including the SET SYSTEM instruction (SYS(49)) is trans-
ferred to the C200HX/HG/HE, the operating parameters set by this instruction
will be transferred to the C200HX/HG/HE's PC Setup area (DM 6600, DM
6601, and DM 6655) and overwrite any current settings. Be sure to confirm
that the settings in these words are correct before using the PC after program
transfer.
Section 1-8
Capability
C200HS
Available in the
C200HS-CPU2j-E
/3j-E
Available in all models
Available in the
C200HS-CPU3j-E
---
---
1 Unit (8 inputs)
---
Normal mode: 10 ms
High-speed mode: 1 ms
(Always 10 ms when a
SYSMAC NET Link or
SYSMAC LINK is used.)
NT Link (1:1)
10.8 ms max.
(1 operating level)
Possible from the
Peripheral Port.
10 ms in any mode