Special I/O Unit Instructions
SR Bits and the Termination
Code
Flags
Example
00000
25201
00101
00100
00100
25200
00100
25201
360
The instruction's termination code is output to SR 237 after CMCR(––) is
executed. Also, SR 252 contains flags that indicate the instruction's completion
status (normal/error) and the execution status for operating levels 0 and 1. The
following table shows the function of these bits.
Word
Bit(s)
SR 237 00 to 07 Termination code output area for operating level 0 after
execution of CMCR(––).
08 to 15 Termination code output area for operating level 1 after
execution of CMCR(––).
SR 252 00
Error Flag for operating level 0 after execution of CMCR(––)
01
ON when CMCR(––) can be executed for operating level 0
03
Error Flag for operating level 1 after execution of CMCR(––)
04
ON when CMCR(––) can be executed for operating level 1
The following table shows the meaning of the termination codes.
Code
00
Normal completion
01
Parameter error such as offset, file size, or number of words to read
02
Disk full, file I/O error, or file type error
03
Non-existent file specified
04
Comparison or search failed
05 to FE
Undefined
FF
Process number error
ER:
The content of a word containing an indirect DM/EM address is not BCD
or the DM/EM area boundary has been exceeded.
DM 6144 through DM 6655 has been used for D.
The execution enabled flag for the specified operating level (SR 25201
or SR 25204) was OFF.
The operating level specified was not 0 or 1.
By turning IR 00000 OFF → ON → OFF, 100 words of DM data starting from
DM 0100 are written to the file G:\DMSAVE.DAT (Memory Card, slot 1). The DM
area settings are shown after the ladder diagram.
S
KEEP
00100
R
@MOV(21)
#0901
DM 0000
@CMCR(––)
DM 0000
DM0098
000
00300
DIFU(013)00101
Function
Meaning
SR 25201: Execution enabled flag for
operating level 0.
Operating level 0
Write file (Create new file.)
(One-word comma delimiter file)
Executes instruction with process
number 1. (Write file)
IR 00300: Output when error occurs in
execution of CMCR(––).
IR 00101: Ends execution of CMCR(––).