Omron C200HX Operation Manual page 513

Hide thumbs Also See for C200HX:
Table of Contents

Advertisement

Host Link Commands
Execution Conditions
End Codes
10-3-31 TEST–– TS
Command Format
Response Format
PC Settings
Execution Conditions
End Codes
Commands
Single
OK
An end code of 14 (format error) will be returned if the length of the command is
incorrect.
End code
00
Normal completion
13
FCS error
14
Format error
18
Frame length error
Returns, unaltered, one block of data transmitted from the host computer.
Specify any characters other than the carriage return (CHR$(13)).
1
0
x 10
x 10
@
T
S
Node no.
Header
code
The same characters specified in the command will be returned unaltered if the
test is successful.
1
0
x 10
x 10
@
T
S
Node no.
Header
code
PC Mode
RUN
MONITOR
OK
OK
Commands
Single
OK
An end code of 14 (format error) will be returned if a terminator isn't received in
the first frame.
End code
13
FCS error
14
Format error
18
Frame length error
Multiple
Single
---
OK
Contents
122 characters max.
Characters
122 characters max.
Characters
PROGRAM
Write-protected
OK
OK
Multiple
Single
---
OK
Contents
Section 10-3
Responses
Multiple
---

FCS
Terminator

FCS
Terminator
UM Area
Read-protected
OK
Responses
Multiple
---
495

Advertisement