Inputting, Modifying, and Checking the Program
!
Caution
Key Sequences
Example
Before Insertion:
00100
00101
00201
00102
To delete an instruction, display the instruction word of the instruction to be
deleted and then press DEL and the up key. All the words for the designated
instruction will be deleted.
Be careful not to inadvertently delete instructions; there is no way to recover
them without re-inputting them completely.
When an instruction is inserted or deleted, all addresses in Program Memory
following the operation are adjusted automatically so that there are no blank
addresses or no unaddressed instructions.
The following mnemonic code shows the changes that are achieved in a pro-
gram through the key sequences and displays shown below.
00104
00103
00201
00105
END(01)
The following key inputs and displays show the procedure for achieving the pro-
gram changes shown above.
Original Program
Address
Instruction
Operands
00000
LD
00001
AND
00002
LD
00003
AND NOT
00004
OR LD
00005
AND
00006
AND NOT
00007
OUT
00008
END(01)
Before Deletion:
00100
00101
00201
00102
Section 4-7
00100
00101
00201
00102
––
00103
00104
00201
––
00105
00103
00104
00201
Delete
END(01)