Omron C200HX Operation Manual page 499

Hide thumbs Also See for C200HX:
Table of Contents

Advertisement

Host Link Commands
PC Settings
Execution Conditions
End Codes
10-3-20 SV CHANGE 1 –– W#
Command Format
1
0
x 10
x 10
@
W
#
Node no.
Header
code
PC Mode
RUN
MONITOR
OK
OK
Commands
Single
OK
An end code of 04 (address over) will be returned if the program address is
above the highest program address but less than 65,536 (32,768 in the
C200HS).
An end code of 14 (format error) will be returned if the length of the command is
incorrect.
An end code of 15 (entry number data error) will be returned if the program ad-
dress exceeds the 65,535 maximum (32,767 in the C200HS), the program ad-
dress isn't specified in BCD, or the mnemonic/SV operands are incorrect.
An end code of 16 (command not supported) will be returned if the specified
instruction doesn't exist in the program.
End code
00
Normal completion
04
Address over
13
FCS error
14
Format error
15
Entry number data error
16
Command not supported
18
Frame length error
23
User memory protected
Searches for the first instance of the specified TIM, TIMH(15), CNT, CNTR(12),
or TTIM(87) instruction in the user's program and changes the SV to new
constant SV specified in the second word of the instruction.
3
OP1 OP2 OP3 OP4
x 10
Mnemonic
Timer/counter
(0000 to 0511)
Use all four characters to specify the timer or counter instruction's mnemonic.
Add a space to the end of a TIM or CNT mnemonic to make it 4 characters long.
Instruction name
TIMER
HIGH-SPEED TIMER
COUNTER
REVERSIBLE COUNTER
TOTALIZING TIMER
PROGRAM
Write-protected
OK
Multiple
Single
---
Contents
2
1
0
3
2
x 10
x 10
x 10
x 10
x 10
SV (0000 to 9999)
Mnemonic
OP1
OP2
T
I
T
I
C
N
C
N
T
T
Section 10-3
UM Area
Read-protected
OK
---
Responses
Multiple
OK
---

1
0
x 10
x 10
FCS
Terminator
TC number
range
OP3
OP4
M
(Space) 0000 to 0511
M
H
T
(Space)
T
R
I
M
481

Advertisement

Table of Contents
loading

This manual is also suitable for:

C200hgC200he

Table of Contents