Omron C200HX Operation Manual page 319

Hide thumbs Also See for C200HX:
Table of Contents

Advertisement

Step Instructions
00001 (SW A1)
00001 (SW A1)
00003 (SW A2)
00004 (SW B2)
00005 (SW D)
Address
Instruction
00000
LD
00001
AND NOT
00002
SNXT(09)
00003
LD NOT
00004
AND
00005
SNXT(09)
00006
STEP(08)
Process A
00100
LD
00101
SNXT(09)
00102
STEP(08)
The program for this process, shown below, starts with two SNXT(09) instruc-
tions that start processes A and B. Because of the way 00001 (SW A1) and
00002 (SB B1) are programmed, only one of these will be executed to start either
process A or process B. Both of the steps for these processes end with a
SNXT(09) that starts the step for process C.
00002 (SW B1)
00002 (SW B1)
Process A
Process B
Process C
Operands
Address
00001
00002
HR
0000
00001
00002
HR
0001
HR
0000
00003
HR
0002
HR
0001
SNXT(09) HR 0000
SNXT(09) HR 0001
Process A started.
STEP(08) HR 0000
Process A reset.
SNXT(09) HR 0002
Process C started.
STEP(08) HR 0001
Process B reset.
SNXT(09) HR 0002
Process C started.
STEP(08) HR 0002
Process C reset.
SNXT(09) HR 0003
STEP(08)
Instruction
Operands
Process B
00100
LD
00101
SNXT(09)
HR
00102
STEP(08)
HR
Process C
00200
LD
00201
SNXT(09)
HR
00202
STEP(08)
---
Section 5-24
00004
0002
0002
00005
0003
301

Advertisement

Table of Contents
loading

This manual is also suitable for:

C200hgC200he