Special Math Instructions
Example 2
AD001 DA001
#0
#1
This example shows a PID control program using PID(––).
Amplifier (See note below.)
Amplifier (See note below.)
Note Motors and heaters cannot be directly connected from an Analog Output Unit.
An amplifier (i.e., a current amplification circuit) is required.
CPU
Unit
Fan (Output word IR 111)
Temperature sensing element
(Output word IR 100)
Heater (Output word IR110)
Section 5-21