Removing an MX2020 Extended Craft Interface

To remove the extended craft interface (see
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis.
2. Detach any external devices connected to the craft interface.
3. Flip the extended craft interface panel up to access the ribbon cable. Use two fingers to squeeze the
release latches on the sides of the connector to disconnect it from the backside of the extended craft
interface.
4. Remove the screws from the top corners on each side of the extended craft interface using a 4-mm
Allen wrench.
5. Remove the remaining screw from the lower corner on each side using a a Phillips (+) screwdriver
(number 1 or 2).
6. Pull the extended craft interface panel away from the router and set aside.
7. Squeeze the release latches on the sides of the ribbon cable connector to disconnect the cable from
the chassis, if necessary.
Figure 252: Removing the Extended Craft Interface