Figure 156: Console and Auxiliary Cable Connector
Table 94: Console and Auxiliary Ports on the MX2020 CB-RE
Function No.
1
2
RELATED DOCUMENTATION

Connecting the MX2020 Router to a Network for Out-of-Band Management | 333

Connecting an MX2020 Router to an External Alarm-Reporting Device | 336

Connecting an MX2020 Router to an External Alarm-Reporting Device
To connect the router to external alarm-reporting devices, attach wires to the RED and YELLOW relay
contacts on the craft interface, (see
yellow alarm LED on the craft interface also activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router, (see
Table 92 on page
337). They accept wire of any gauge between 28 AWG and 14 AWG (0.08 and 2.08 mm
the wire which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
To connect an external device to an alarm relay contact (see
1. Prepare the required length of wire with gauge between 28 AWG and 14 AWG (0.08 and 2.08 mm
2. While the terminal block is not plugged into the relay contact, use a 2.5 mm flat-blade screwdriver to
loosen the small screws. With the small screws facing left, insert wires into the slots in the front of the
block based on the wiring for the external device. Tighten the screws to secure the wire.
Label
AUX
CONSOLE
Figure 152 on page
Description
Connect a laptop, modem, or other auxiliary
unit.
Connect a laptop or console terminal to
configure the MX2020 router.
337). A system condition that triggers the red or
Figure 152 on page
2
);
337).
2
).
340

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents