Troubleshooting A Modular Port Concentrator (Mpc) - Juniper MX2020 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX2020:
Table of Contents

Advertisement

MX2000 Modular Interface Card (MIC) Description | 65
Maintaining MX2020 MICs | 525
Maintaining Cables That Connect to MX2020 MPCs or MICs | 529
Replacing an MX2020 MIC | 553

Troubleshooting a Modular Port Concentrator (MPC)

Problem
Description: The following LEDs indicate a problem with an MPC:
The red FAIL LED above the MPC is lit.
The green OK LED above the MPC is not lit.
Solution
To troubleshoot an MPC:
1. Monitor the green LED labeled OK above the MPC on the craft interface as soon as an MPC is seated
in an operating router.
NOTE:
The Control Board and Routing Engine (CB-RE) downloads the MPC software to
it under two conditions: The MPC is present when the CB-RE boots Junos OS, and the
MPC is installed and requested online through the CLI or push button on the front panel.
The MPC then runs diagnostics, during which the OK LED blinks. When the MPC is online
and functioning normally, the OK LED lights green steadily.
2. Look at the display on the craft interface to check the status of the MPC and the MICs that are plugged
into it.
3. Verify that the MPC is properly seated in the top and bottom backplanes of the adapter card (ADC).
Check that each knob has been turned clockwise and is tight.
4. Check the OK/FAIL LED on the MPC, and OK and FAIL line card LEDs, LC0 through LC9, and LC10
through LC19 on the craft interface. When the MPC is online and functioning normally, the OK LED
lights green steadily.
5. Check the status of an MPC using the following CLI command: show chassis fpc command to check
the status of installed MPCs. As shown in the sample output, the value Online in the column labeled
State indicates that the MPC is functioning normally:
683