2-25. Operating Status Monitoring

F3SG-RA Series
F3SG-RE Series
2-25-1. Overview
I/O information and the state of F3SG-RA can be read out with the Configuration Tool. This function is
only for F3SG-RA Configuration Tool.
Make sure the Position 8 of the DIP Switch is set to Configuration Tool Enabled to activate the settings by the
Configuration Tool.
Refer to Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User's Manual for more
information on setting this function by the Configuration Tool.
The Operating Status Monitoring is not available for the F3SG-RE.
2-25-2. Readout Information
The user can view the following information related to a receiver.
The information is displayed in a block in case of a cascade connection.
Information Name
RESET input
Muting A /Pre-Reset Input
Muting B Input
Safety output 1
Safety output 2
Auxiliary output
Power supply voltage
Interlock information
Muting information
Override information
Sequence error information
Blanking bream unblocked information Linked to the state where the blanking beam is unblocked
DIP-SW input information
Push-SW input information
F3SG-R
104
User's Manual
X
Linked to Reset/External Device Monitoring (EDM)/Override Input
Linked to Muting A/Pre-Reset Input
Linked to Muting B Input
Linked to safety output 1
Linked to safety output 2
Linked to auxiliary output
Indicates supplied source voltage
Linked to Interlock state
Linked to Muting state
Linked to override state
Linked to Muting sequence error state or Interlock sequence error state
Linked to the input signal of DIP Switch
Linked to the input signal of Push Switch
Description