Parts Replacement; Obtaining Tools; Replacement Guidelines; System Reliability - Huawei FusionServer Pro CH121 V5 V100R005 Maintenance And Service Manual

Compute node
Hide thumbs Also See for FusionServer Pro CH121 V5 V100R005:
Table of Contents

Advertisement

FusionServer Pro CH121 V5 Compute Node
Maintenance and Service Guide

4.1 Obtaining Tools

4.2 Replacement Guidelines

4.3 Field Replaceable Units
4.1 Obtaining Tools
Ensure that the following tools are available:
l
l
l
l
l
l
l
4.2 Replacement Guidelines

4.2.1 System Reliability

The CH121 V5 must meet the following requirements for system reliability:
l
l
l
l
l
Issue 06 (2019-08-10)
ESD wrist strap or ESD gloves
Protective gloves
ESD bags
Box cutter
M3 Phillips screwdriver
Flat-head screwdriver
T20 Torx screwdriver
To ensure optimal heat dissipation, ensure that the server is completely filled with
components or filler panels.
If the processor socket is not installed with a processor, install a socket cover.
If the CH121 V5 is configured with only one processor, the processor must be installed
in socket CPU 1 and memory modules must be configured for CPU 1.
Install air ducts above memory slots.
The CMOS battery has sufficient power.
Processors 1 and 2 use different heat sinks. The following heat sink configurations are
available: