FusionServer Pro CH121 V5 Compute Node
Maintenance and Service Guide
Figure 4-14 Position of the supercapacitor
Step 7 Install the supercapacitor holder.
1.
2.
Figure 4-15 Installing the supercapacitor holder
Step 8 Install the supercapacitor.
1.
2.
Issue 06 (2019-08-10)
Place the supercapacitor holder vertically on the RAID controller card. See (1) in
4-15.
Align the screws of the supercapacitor holder with the screw holes on the RAID
controller card, and tighten the screws. See (2) in
Push the supercapacitor into the capacitor holder horizontally until the supercapacitor is
secured by the plastic latches. See (1) in
Connect the cable to the supercapacitor. See (2) in
Copyright © Huawei Technologies Co., Ltd.
Figure
4-15.
Figure
4-16.
Figure
4-16.
4 Parts Replacement
Figure
66