Step 2 Power off the compute node.
For details, see
Step 3 Remove the compute node.
For details, see
Step 4 Place the compute node on the ESD workstation.
Step 5 Remove the cover.
For details, see
Step 6 Determine the position of the mezzanine card.
Issue 06 (2019-08-10)
Switch configuration (such as VLAN configuration of Ethernet switches and zoning
configuration of FC switches)
For details, see the configuration guide of the switch you use.
LUN configuration in the FC disk array
For details, see the configuration guide of the FC disk array you use.
NIC port numbers
– If Windows is used, query the port numbers in the network sharing center.
– If VMware ESXi is used, run the esxcli network nic list command on the CLI.
– If Linux is used, run the ifconfig -a command on the CLI.
WWPN of the NIC
– If Windows is used, use the HBA card management tool to query the WWPN.
– If VMware ESXi is used, run the esxcli storage san fc list command on the CLI.
– If Linux is used, run the cat /sys/class/fc_host**/port_name command.
NIC bus information
On the CLI, run the lspci|grep -i eth command to query the NIC chip name, and obtain
the bus number based on the NIC chip name.