FusionServer Pro CH121 V5 Compute Node
Maintenance and Service Guide
Step 10 Power on the compute node.
For details, see
----End

4.3.23 Removing the Mainboard and Compute Node Case

Procedure
Step 1 Record the iBMC, BIOS, and CPLD firmware versions of the mainboard.
You can obtain the firmware version information on Information > System Info > Product
Info > Mainboard Info of the iBMC WebUI or by running the ipmcget -d version command
on the iBMC CLI.
Step 2 Confirm the iBMC and BIOS configuration for quick recovery after replacing the mainboard.
Step 3 Export the iBMC/BIOS configuration files. After the replacement, you can import the
configuration files to quickly restore the server configuration.
For details, see iBMC WebUI > Configuration > Import/Export in
E9000 Server iBMC User
Step 4 Power off the compute node.
For details, see
Step 5 Remove the compute node.
For details, see
Step 6 Place the compute node on the ESD workstation.
Step 7 Remove the cover.
For details, see
Step 8 Determine the position of the mainboard and the compute node case.
Issue 06 (2019-08-10)
3.2 Power-On
NOTE
l The iBMC supports import and export of configuration files from version 2.32.
l After replacing the mainboard, import the iBMC and BIOS configuration files that are exported
from the iBMC. However, the exported configuration files do not contain password information.
You need to manually configure the password for the iBMC user. For details, see "Import/Export" in
FusionServer Pro E9000 Server iBMC User
l The iBMC and BIOS configuration files exported from the iBMC contain the configuration list. For
details, see "Configuration File Description" in
Guide.
l If the iBMC of the mainboard to be replaced cannot be accessed or the iBMC and BIOS
configuration files are not exported before the mainboard is replaced, you need to manually
configure the iBMC and BIOS after replacing the mainboard.
3.1 Power-Off
3.3 Removing a CH121
3.5 Removing the
Copyright © Huawei Technologies Co., Ltd.
Procedure.
Guide.
Guide.
FusionServer Pro E9000 Server iBMC User
Procedure.
V5.
Cover.
4 Parts Replacement
FusionServer Pro
101

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents