Environmental Specifications - Huawei FusionServer Pro CH121 V5 V100R005 Maintenance And Service Manual

Compute node
Hide thumbs Also See for FusionServer Pro CH121 V5 V100R005:
Table of Contents

Advertisement

FusionServer Pro CH121 V5 Compute Node
Maintenance and Service Guide

11.2 Environmental Specifications

Table 11-2 Environmental specifications
Category
Temperature
Relative humidity (RH,
non-condensing)
Altitude
Corrosive gaseous
contaminant
Issue 06 (2019-08-10)
Specifications
l Operating temperature: 5°C to 40°C (41°F to 104°F)
(ASHRAE Classes A2 and A3 compliant)
l Storage temperature: –40°C to +65°C (–40°F to +149°F)
l Long-term storage temperature: 21°C to 27°C (69.8°F to
80.6°F)
l Maximum temperature change rate: 20°C/h (36°F/h)
NOTE
®
If Intel
Gold 6144, 6146, 6154) are used, the maximum operating temperature
supported is 35°C (95°F).
l Operating humidity: 5% to 85%
l Storage humidity: 5% to 95%
l Long-term storage humidity: 30% to 69%
l Maximum change rate: 20%/h
l Operating altitude ≤ 3050 m (10006.44 ft)
– When the server configuration complies with ASHRAE
Class A2 standards and the altitude is above 900 m
(2952.76 ft), the highest operating temperature
decreases by 1°C (1.8°F) for every increase of 300 m
(984.24 ft).
– When the server configuration complies with ASHRAE
Class A3 standards and the altitude is above 900 m
(2952.76 ft), the highest operating temperature
decreases by 1°C (1.8°F) for every increase of 175 m
(574.14 ft).
l HDDs cannot be used at an altitude of over 3000 m (9842.4
ft).
Maximum corrosion product thickness growth rate:
l Copper corrosion rate test: 300 Å/month (meeting level G1
requirements of the ANSI/ISA-71.04-2013 standard on
gaseous corrosion)
l Silver corrosion rate test: 200 Å/month
Copyright © Huawei Technologies Co., Ltd.
®
Xeon
Scalable processors (Platinum 8180, 8180M, 8168 or
11 Product Specifications
143

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents