Operating Temperature Limits
Storage Temperature Limits
Temperature Effect
Supply Pressure Effect
Ambient Humidity
Humidity Effect
Electromagnetic Compatibility
Electrostatic
Vibration Influence
Measured at SVI FF Housing
© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
Table 10 Environmental Specifications
-40° F to 185° F (-40° C to 85° C)
-58° F to 185° F (-50° C to 85° C)
< 0.005% /° F typical; -40° F to 180° F (< 0.01% /° C typical; -40° C to 82° C)
0.05% per psi unit (.73% per bar unit)
10 to 95% non-condensing
Less than 0.2% after 2 days at 104° F (40° C), 95% Relative Humidity.
IEC\EN61326-1 Ed 2 compliant
Immunity Table 62 Industrial and Electromagnetic Environment
Emission Limits CISPR 11 Group 1 Class A
4 mm at 5 - 15 Hz - Negligible
2 G at 15 - 150 Hz Less than 2 % of span
1 G at 150 - 2000 Hz - Less than 2% of span