Mechanical Installation; Overview; Svi Ff Positioner Types; Single Acting Positioner Description - GE Baker Hughes Masoneilan SVI FF Installation And Operation Manual

Digital positioner
Table of Contents

Advertisement

4. Mechanical Installation

Overview

The SVI FF single acting (Figure 11 on page 37) and double acting (Figure 16 on page 42) are high
performance, digital valve positioners that combine a local display with remote communication
and diagnostic capabilities. The SVI FF is available with a variety of options to fulfill diverse
applications.
NOTE

SVI FF Positioner Types

SVI FF positioner types include:
"Single Acting Positioner Description" on page 35, including a high flow version
"Double Acting Positioner Description" on page 41

Single Acting Positioner Description

The supply and output connections for the SVI FF (Figure 9), located on bottom of the pneumatic
block, are tapped 1⁄4" NPT. Output is toward the front, supply is toward the back. Two pressure
gauges, output on top, supply on bottom, are located on the front of the pneumatic block.
The supply and output connections for the SVI FF High Flow (Figure 10), located on bottom and
leftside of the pneumatic block, are tapped 1⁄2" NPT.
Maximum allowable air supply pressure to the SVI FF varies according to actuator, valve size,
and valve type. See Pressure Drop tables in valve specification sheets to determine the correct
positioner supply pressure. Minimum supply pressure must be 5 psi to 10 psi (.345 bar - .69 bar)
(34.485 - 68.97 kPa) above maximum spring range but cannot exceed the rated actuator
pressure.
© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
Prior to beginning the installation process review the "Safety
Information" on page 9.