6.3 Access in emergency situations (Emergency mode)

6.3.1 Activating emergency mode
The emergency mode is similar to the release mode: The locking device remains permanently
coupled so that the door can always be opened without necessitating the use of a locking media.
In contrast to the release mode, the emergency mode cannot be cancelled by the Release-Master,
but only through the Emergency-Key and has the highest priority amongst all opening modes. see
"Hierarchy of the opening modes"
Required master media:
Emergency-Key
l
The Emergency-Key must first be authorised for the locking device with which it is to be
used (see
"Authorising additional master media"
Procedure:
1. Hold the locking media before the reading field of the locking device.
After ca. 1 second, the following signal appears:
1x short green
If the locking device already lights up green while the Emergency-Key is being read, but no
green flashing signal appears after one second, emergency mode is already active.
2. Remove the Emergency-Key from the reading field of the locking device.
The locking device is now in emergency mode. Permanent access without locking media is now
possible because the coupling of the locking device is permanently engaged. The emergency mode
can be deactivated by Emergency-Key only.
Troubleshooting:
Signalling
The Emergency-Key could be read but is
not authorised for this locking device.
Long shield ILS
6.3   Access in emergency situations (Emergency mode)
on page 84.
Reason
Authorise the Emergency-Key.