10.3   Error signalling

10.3 Error signalling

Signalling
Reason
After reading a master media:
Master media error:
a) The master media is not authorised.
b) For master media, which control the
opening modes: An opening mode with
higher priority is active (see
the opening modes"
c) The master media cannot be read
because of the locking device variant (e.g.
Program-Master for V-NET devices).
After reading a master media or locking media:
1 The media is not authorised for this
device.
or
2. The media could not be read completely
because:
a) it was not held long enough in the
reading field .
b) The master media or the V-NET locking
media has wrong system Identification
code.
c) a LINE locking media was held in the
reading field of a V-NET device.
Additionally after reading the authorised or unauthorised locking media:
The battery alarm indicates that the
batteries are going to be empty soon (see
or
"Maintenance"
or
Page 106 of 141
"Hierarchy of
on page 84).
on page 91).
Solution
a) Authorise the master media.
b) Deactivate the opening mode with
the higher priority.
c) Check whether the master media
can be used with the concerned
device types.
1. Authorise the media for this device
or
2a) Keep the media for a longer
period in the reading field of the
locking device.
2b) Use a master media or V-NET
locking media with the right system
identification code.
2c)LINE locking media could not be
read by V-NET devices.
Replace the batteries(see
"Maintenance"
on page 91).
Long shield ILS