CEStronics CES OMEGA FLEX Manual

CEStronics CES OMEGA FLEX Manual

Signalling of the locking devices

Advertisement

Quick Links

CES OMEGA FLEX
Locking devices
Signalling of the locking devices
Electronic handle sets
Electronic cylinder
English
Version VB

Advertisement

Table of Contents
loading

Summary of Contents for CEStronics CES OMEGA FLEX

  • Page 1 CES OMEGA FLEX Locking devices Signalling of the locking devices Electronic handle sets Electronic cylinder English Version VB...
  • Page 2: Table Of Contents

    Contents 1 Signalling during operation 1.1 Opening the locking device with a locking medium 1.2 Activating the office mode 1.3 Deactivating the office mode 2 Signalling while using the master media 2.1 Authorising System-Master 2.2 Authorising additional master media 2.3 Deleting master media 2.4 Deleting System-Master 2.5 Authorising locking media 2.6 Deleting locking media authorisations...
  • Page 3: Signalling During Operation

    1   Signalling during operation 1 Signalling during operation 1.1 Opening the locking device with a locking medium Procedure: 1. Hold an authorised locking media for ca. 1 second in the reading field of the locking device (maximum distance ca. 10 mm). The following signal appears: 1x short green and 1x short beep You can open the door by pressing the lever handle for a certain period.
  • Page 4: Activating The Office Mode

    1   Signalling during operation Signalling Reason Solution The locking media is not authorised. Have the locking media authorised by the administrator of the OMEGA FLEX system. The locking media is authorised but the If the block time or block mode is active, a block time or block mode is active.
  • Page 5: Deactivating The Office Mode

    1   Signalling during operation Troubleshooting: Problem/Signalling Reason Solution No signal after ca 2 seconds. The The locking device is not authorised Have the locking device office mode is not active. The for the office function. authorised for the office function coupling of the locking device by the system administrator.
  • Page 6 1   Signalling during operation Signalling Reason Solution because the locking media is not the office function by the system authorised for the office function. administrator. not shown. Signalling of OMEGA FLEX Locking devices Page 6 of 39...
  • Page 7: Signalling While Using The Master Media

    2   Signalling while using the master media 2 Signalling while using the master media 2.1 Authorising System-Master 2.2 Authorising additional master media 2.3 Deleting master media 2.4 Deleting System-Master 2.5 Authorising locking media 2.6 Deleting locking media authorisations 2.7 Deleting all locking media authorisations simultaneously 2.8 Setting opening period 2.9 Activating release mode 2.10 Deactivating release mode...
  • Page 8: Authorising System-Master

    2   Signalling while using the master media 2.1 Authorising System-Master Each locking device of an OMEGAFLEX system must first become familiar with the System - Master of the system so that the System-Master is authorised to authorise additional master media for this locking device. Each OMEGA FLEX system has only one System-Master.
  • Page 9 2   Signalling while using the master media 2. Hold the System-Master again for ca 1 second in the reading field of the locking device and then remove it from the reading field. The following signal appears: 1x long green and 1x long beep The System-Master is now authorised for this locking device.
  • Page 10: Authorising Additional Master Media

    2   Signalling while using the master media 2.2 Authorising additional master media All master media must be authorised prior to their first use. The only exceptions are the RF-Ini- Master (in NET and VA devices) and the RF-Trace-Master. Required master media: System-Master Any master media that needs to be authorised Procedure:...
  • Page 11 2   Signalling while using the master media 3. Hold the System-Master for ca 1 second in the reading field of the locking device to end the “authorise mode. The following signal appears: 1x long green and 1x long beep The “authorise mode” will end automatically after 5 seconds. Die new authorisations remain stored.
  • Page 12: Deleting Master Media

    2   Signalling while using the master media 2.3 Deleting master media The deletion of a Program-Master deletes all locking authorisations which were assigned with this Program-Master. The opening duration set with theTime-Master remains intact even after deletion of the Time-Master. Required master media: System-Master Any master media, that needs to be deleted...
  • Page 13 2   Signalling while using the master media 2. Now you can delete any number of master media one after the other by holding each master media for ca 5 second in the reading field of the locking device. The following signal appears for each master media: 2x short green and 2x short beep 3.
  • Page 14: Deleting System-Master

    2   Signalling while using the master media 2.4 Deleting System-Master Effects of deletion of System-Master Deletion of the System-Master results in deletion of all master media and locking author isations from a locking device. All settings in the locking device, which were made with the OMEGA Client software (e.g. Time profiles, locking media authorisations etc.), remain intact after deletion of the Sys tem-Master.
  • Page 15: Authorising Locking Media

    2   Signalling while using the master media 2.5 Authorising locking media Required media: Program-Master Any locking media that needs to be authorised The Program-Master must first be authorised for the locking device on which it is to be used Procedure: 1.
  • Page 16 2   Signalling while using the master media 3. Hold the Program-Master for ca 1 second in the reading field of the locking device to end the “authorise mode. The following signal appears: 1x long green and 1x long beep The “authorise mode” will end automatically after 5 seconds. Die new authorisations remain stored.
  • Page 17: Deleting Locking Media Authorisations

    2   Signalling while using the master media 2.6 Deleting locking media authorisations A locking media can be deleted from a locking device only with the same Program-Master with which it was authorised. Required media: Program-Master with which the locking media was authorised Authorised locking media, whose authorisation is to be deleted.
  • Page 18 2   Signalling while using the master media 3. Hold the Program-Master for ca 1 second in the reading field of the locking device to end the “delete locking media” mode The following signal appears: 1x long green and 1x long beep The “delete locking media mode”...
  • Page 19: Deleting All Locking Media Authorisations Simultaneously

    2   Signalling while using the master media 2.7 Deleting all locking media authorisations simultaneously Only those locking media authorisations are deleted, which were added by the same Program-Master, which is also used for deletion. Procedure: 1. Hold the Program-Master before the reading field of the locking device. After ca.
  • Page 20: Setting Opening Period

    2   Signalling while using the master media 2.8 Setting opening period The opening duration is the length of time during which the locking device remains coupled, after an authorised locking media was held in the reading field of the locking device. The longer the opening duration, the more time people have to operate the locking device after the authenticating with a locking media.
  • Page 21: Activating Release Mode

    2   Signalling while using the master media 2.9 Activating release mode A locking device which is in release mode remains permanently coupled, i.e. the door can be opened permanently without necessitating the use of any locking media. Required master media: Release-Master The Program-Master must first be authorised for the locking device on which it is to be used...
  • Page 22: Deactivating Release Mode

    2   Signalling while using the master media 2.10 Deactivating release mode Required master media: Release-Master The Program-Master must first be authorised for the locking device on which it is to be used Procedure: 1. Hold the Release-Master before the reading field of the locking device. After ca.
  • Page 23: Activating Block Mode

    2   Signalling while using the master media 2.11 Activating block mode A locking device in block mode remains permanently uncoupled, i.e. the door cannot be opened. An access even with an authorised locking media is no more possible. Required master media: Block-Master The Program-Master must first be authorised for the locking device on which it is to be used...
  • Page 24: Deactivating Block Mode

    2   Signalling while using the master media 2.12 Deactivating block mode Required master media: Block-Master The Program-Master must first be authorised for the locking device on which it is to be used Procedure: 1. Hold the Block-Master before the reading field of the locking device. After ca.
  • Page 25: Activating Emergency Mode

    2   Signalling while using the master media 2.13 Activating emergency mode Required master media: Emergency-Key The Emergency-Key must first be authorised for the locking device with which it is to be used Procedure: 1. Hold the locking media before the reading field of the locking device. After ca.
  • Page 26: Deactivating Emergency Mode

    2   Signalling while using the master media 2.14 Deactivating emergency mode Required master media: Emergency-Key The Emergency-Key must first be authorised for the locking device with which it is to be used Procedure: 1. Hold the locking media before the reading field of the locking device that is in emergency mode.
  • Page 27: Activating Online Mode

    2   Signalling while using the master media 2.15 Activating online mode Required master media: RF-Ini-Master For the activation of online mode it is not necessary to authorise the RF-Ini-Master in advance. Procedure: 1. Hold the RF-Ini-Master for ca 1 second in the reading field of the locking device. Following signals appear: A: 1x short green and 1x short beep = successfully connected to the Access-Point...
  • Page 28 2   Signalling while using the master media Troubleshooting: Signalling Reason Solution While the RF-Ini-Master is held in the reading field: The locking device does not belong to the The online mode is not available for this variant NET or VA . locking device.
  • Page 29: Deactivating Online Mode

    2   Signalling while using the master media 2.16 Deactivating online mode Required master media: RF-Ini-Master For the deactivation of the online mode it is not necessary to authorise the RF-Ini-Master in advance. Procedure: 1. Halten Sie den RF-Ini-Master ca. zwei Sekunden lang vor das Lesefeld des Schließgeräts. The following signal appears: 2x short green and 2x short beep 2.
  • Page 30: Checking Quality Of Wireless Connection

    2   Signalling while using the master media 2.17 Checking quality of wireless connection Required master media: RF-Trace-Master The RF-Trace-Master is ready for immediate use and does not have to authorised first. Procedure: 1. Hold the RF-Ini-Master for ca 1 second in the reading field of the locking device. The following signal appears: 1x short green and 1x short beep Signalling of OMEGA FLEX Locking devices...
  • Page 31 2   Signalling while using the master media 2. The locking device shows now the quality of the wireless connection: Very good sufficient weak No wireless connection The Access-Point associated with the Update-Terminal shows during wireless connection test the quality of the wireless connection with the same signalling as the locking device. 3.
  • Page 32: Transmitting Programming Jobs With An Rf-Stick To A Locking Device

    2   Signalling while using the master media 2.18 Transmitting programming jobs with an RF-Stick to a locking device Required master media and administration devices: RF-Stick-Master RF-Stick PC with OMEGA Client installed Procedure for creating programming jobs: 1. Start the OMEGA Client and log in with your user name and password. 2.
  • Page 33 2   Signalling while using the master media 1. Proceed with your PC and the RF-Stick connected to it to the locking device into which the programming jobs are to be transmitted. If you want to transmit the programming jobs into multiple locking devices, you can freely choose the sequence in which you look for the locking devices.
  • Page 34 2   Signalling while using the master media Signalling Reason Solution again. Signalling of OMEGA FLEX Locking devices Page 34 of 39...
  • Page 35: Signalling After Battery Insertion

    3   Signalling after battery insertion 3 Signalling after battery insertion Signalling Meaning Start sequence for offline locking devices: No error Start sequence for online locking devices: Device is online and is connected to the Access-Point Start sequence for online locking devices: Device is online but no connection to Access-Point is possible Firmware error.
  • Page 36: Battery Warning System

    4   Battery warning system 4 Battery warning system When the battery power becomes weak, the locking device displays additional signals if authorised or unauthorised locking media were held in the reading field of the locking device or the locking device couples, e.g. after the release or emergency mode was activated. These additional signals are the battery warnings.
  • Page 37: Error Signalling

    5   Error signalling 5 Error signalling Signalling Reason Solution After reading a master media: Master media error: a) The master media is not authorised. a) Authorise the master media. b) For master media, which control the b) Deactivate the opening mode with opening modes: An opening mode with the higher priority.
  • Page 38 5   Error signalling System error If system errors are present, they are signalled after to the following actions: after reading the authorised locking media after attempting to put handle set in release mode or emergency mode after the start sequence (insertion/connecting the batteries) Signalling Reason Solution...
  • Page 39 C. Ed. Schulte GmbH United Kingdom Zylinderschlossfabrik CES Security Solutions Ltd. Friedrichstraße 243 Unit 4 Kendon Business Park D-42551 Velbert Maritime Close, Medway City Estate +49 2051 204 0 Rochester, Kent ME2 4JF +44 1 634713369 +49 2051 204 229 +44 1 634786833 info@ces.eu info@uk.ces.eu...