2. Hold the RF-Stick-Master briefly in the reading field of the locking device.
The following signal appears:
1x short green
3. The locking device searches now for an RF-Stick nearby.
The distance between the locking device and the RF-Stick may not exceed ten meters.at
the maximum.
As soon as the RF-Stick has been detected, the transmission begins. During transmission, the
locking device flashes green.
During transmission the following happens:
- All programming jobs for this locking device are transmitted to this locking device.
During programming, the programming status display shows the progress in
percentage.
- All events stored in the locking device, which were not available to the OMEGA
Client yet, will be copied into the OMEGA Client.
- The clock is set.
If no programming jobs are available, only the events are copied and the clock
is set. In this case, the locking device does not flash during the transmission.
After all data has been transmitted, the RF-Stick and the locking device are disconnected
automatically. After transmission completion, the programming job is deleted from the
"Programming status" list.
The programming job transmission is completed when the locking device signals 1x long green 1x
long beep.
Troubleshooting:
Signalling
During step 2:
The locking device cannot detect any RF-
Stick nearby.
Long shield ILS
Reason
Move with a properly connected RF-Stick
closer to the locking device and try to
transmit the programming jobs once
again.