4.6   Assembly Option S (for Short shield holes)
Assembly preparation - Long shield ILS
Assembly on the outside of the door
Page 36 of 141
Before assembling the hardware, check for correct
fit of the coupling module; see
module"
on page 17
1. If a handle set is already existent in the door,
dismantle it. An existing Euro profile cylinder having
appropriate length, can continue to be used with the
Long shield ILS - Option S.
If the door does not have a Euro profile cylinder yet,
it is advisable to assemble it before assembling the
long shield ILS Option S.
You can now start with the assembly.
1. Push one of the
FIXING SCREWS WITHOUT WIRING SLIT
lower screw placement slot of
The fixing rings on the head of the screws serve to
fix the screws in the position that matches the
existing holes.
2. Optional: If a hole already exists at the appropriate
location in the door, you may push the third fixing
screw without wiring slit in the top most screw hole.
3. Hold the
upwards and slide the
CABLES
in the middle screw placement slot of the
WIRING SLIT
.
OUTSIDE FITTING
Ensure that the cable slit of the fixing screws faces
upwards.
Ensure that the cables run through the recess in
the screw head.
"Check the coupling
in the
.
OUTER FITTING
FIXING SCREW WITH
Long shield ILS

Advertisement