2) You delete the Program-Master(see
device. This automatically deletes all locking media authorisations which were added with this
Program-Master.
Note that in case you are using multiple Program-Masters: in both cases only those locking
media authorisations are deleted, which were added by the same Program-Master, which
is used for deletion!
10.2.2 Loss of a locking media for administration with an RF-Stick
A detailed manual is available in the OMEGA Suite Help.
1. Delete the locking media from the OMEGA Client.
Programming jobs are created automatically which remove the authorisations from the relevant
locking devices.
2. Go to the affected locking devices and transmit the programming jobs via the RF-Stick to
the locking devices.
The locking media cannot be used now on the affected locking devices any more.
If you have additionally authorised the locking media by means of a Program-Master for
locking devices, these authorisations were not deleted. Carry out a reprogramming of all
locking devices, for which you have authorised the locking media with a Program-Master.
10.2.3 Loss of a locking media for administration via wireless online network
A detailed manual is available in the OMEGA Suite Help.
1. Delete the locking media from the OMEGA Client.
Programming jobs are created automatically which remove the authorisations from the relevant
locking devices.
The relevant locking devices are programmed via the wireless online network. The locking media
cannot be used now on the affected locking devices any more.
If you have authorised the locking media additionally by means of a Program-Master for
locking devices, these authorisations were not deleted. Carry out a reprogramming of all
locking devices, for which you have authorised the locking media with a Program-Master.
10.2.4 Loss of a locking media for administration via V-NET
In V-NET, the locking media which are not supposed to be in use are not deleted but rather
blocked. The information that a locking media is blocked is stored in the locking media. Locking
Long shield ILS