Help And Troubleshooting; Loss Of A Master Media - CEStronics CES OMEGA FLEX Assembly And Operating Instructions Manual

Electronic handle sets. long shield ils
Hide thumbs Also See for CES OMEGA FLEX:
Table of Contents

Advertisement

10 Help and troubleshooting

10.1 Loss of a master media

CAUTION
The measures described here to restore the security of your OMEGA FLEX system should
only be carried out CES or by CES partner trained on the product.
If you have lost one of the following master media, you must delete that master media from the
locking devices:
Emergency-Key
l
Program-Master
l
Time-Master
l
Release-Master
l
Block-Master
l
RF-Stick-Master
l
To be able to delete the System-Master you must have access to it. If you have lost the
System-Master of your OMEGA FLEX system, contact your CES partner immediately!
The RF-Trace-Master and the RF-Ini-Master cannot be deleted from a locking device
because they are not authorised beforehand.
10.1.1 Deleting master media from a locking device
If you delete one of the master media, which is capable of putting a locking device in a
different mode, the mode of the locking device is retained after deletion.
Exception: Deletion of System-Master. Deletion of the System-Master reverts the locking
devices back to the normal mode.
Long shield ILS
Manipulation of the OMEGA FLEX system possible
If unauthorised persons gain possession of a master media, the OMEGA
FLEX system can be manipulated.
- Keep all your master media at a safe place.
- Make sure that these are not accessible to unauthorised persons.
10.1   Loss of a master media
Page 101 of 141