11.8 Setting opening period

The opening duration is the length of time during which the locking device remains coupled, after
an authorised locking media was held in the reading field of the locking device.
The longer the opening duration, the more time people have to operate the locking device after
the authenticating with a locking media. The maximum opening duration is 180 seconds.
Required master media:
Time-Master
l
The Program-Master must first be authorised for the locking device on which it is to be
used, see
"Authorising additional master media"
Procedure:
1. Hold the Time-Master before the reading field of the locking device.
The locking device starts to transmit flashing signals. Each flashing signal represents 1 second
opening period.
2. Hold the Time-Master before the locking device until the desired opening period is
reached. If, for example, you desire an opening period of 20 seconds, wait for 20 flash
signals
3. Remove the Time-Master from the reading field.
A signal confirming the setting follows:
1x long green
The opening period is now set
The minimum opening period is 2 seconds. If you remove the Time-Master after 1 second
from the reading field, the opening period will be set to 2 seconds.
The maximum opening duration is 180 seconds. Even if you hold the Time-Master longer in
the reading field, the opening period will be set to 180 seconds.