Details On Opening Doors - CEStronics OMEGA FLEX Assembly And Operating Manual

Electronic fitting rfid furniture lock
Hide thumbs Also See for OMEGA FLEX:
Table of Contents

Advertisement

5.1 Details on opening doors

Procedure:
Steps
1. Hold an authorised locking medium in the reading field of the locking device for
approx. 1 second (maximum distance approx. 10 mm).
Locking medium is read and accepted.
The electronic furniture lock is released.
Troubleshooting:
Signal
Cause
The locking medium
The locking medium was not held close enough to
cannot be read (no
the reading field of the locking device.
signal).
The reading field of the locking device was covered
by metallic materials.
Another authorised locking medium was recently
held in the reading field of the locking device and
the opening duration of the locking device has not
yet expired.
The battery is flat.
The locking medium is defective.
4x
short red
The locking medium is not authorised.
The locking medium is authorised but the blocking
time or block mode is active.
1x
long green
The locking medium is authorised and the locking
device is currently in release mode.
RFID furniture lock
5.1   Details on opening doors
Signal
1x
short green
Solution
Hold the locking medium closer to the reading
field of the locking device.
Remove the metallic materials from the
reading field of the locking device.
You can open the door without your locking
medium being read.
Replace the batteries.
Contact the OMEGA FLEX system administrator.
Contact the OMEGA FLEX system administrator.
A locking device cannot be opened by an
authorised locking medium if the blocking time
or block mode is active.
You can also open the door even without an
authorised locking medium.
Page 15 of 84

Advertisement

Table of Contents
loading