en | Central Console, computer setup and programming
6.4.5

Setting receiver parameters

Create or modify the receivers of the transponder using the features of the Point or Area
Data. For configuring Area Data, refer to the Alarm area setup section. The sections below
explain how to configure the receiver points for the transponder.
Entering point number
Each receiver and alert unit connected to the transponder has a unique Point Number
assigned during the system design process. This Point Number ranges from 0 to 63, and
corresponds to a specific bus number and point multiplex address number. The multiplex
address, set by means of switches on the device (receiver or alert unit) itself, must
correspond with the Point Number assigned in the Transponder Database.
There is a one-to-one relationship between the Point Number and the combination of
Multiplex Point Address / Bus Number pair. For example, a device programmed with
Multiplex Point Address location 3 on Bus Number 5 would correspond to the Point Number
29.
Clicking the [?] button to the right of the Point Number text box opens a dialog window
displaying the Point Number in a table. Clicking on any Point Number in the table
automatically closes this window and fills the number in the Point Number field on the
Transponder Database dialog. The Bus number and Point address are also changed to reflect
the selection.
Figure 6.6: Select Point Dialog with "All Points" Selected
This table provides a quick way to select a particular device without having to translate
between the two numbering (Bus Number/Point Address) systems. The three buttons at the
bottom of this dialog allow the user to display: