Security Escort
6.
7.
8.
Tab. 4.3: Wiring – Required pins
9.
Robert Bosch (SEA) Pte Ltd
Go to Channel 1 > Connection. Select "TCP" from the drop down list of Protocol field.
Enter the port number of the transponder in the Local Port field. This port number is the
same number as the one that is set for the transponder in the Transponder Database of
the Security Escort software.
Click the [OK] button to apply the settings.
The connecting cable is a modified male DB9 to male DB25 serial cable. Only 3 wires are
compulsory for the modification of DB9 to DB25 cable as illustrated in the table below.
RS232 Pin Assignment
DB9 Pin Male
Pin
2
3
5
Connect the male DB9 connector to the transponder and the male DB25 connector to the
Lantronix device.
DB25 Pin Male
Pin
2
3
7
Training Manual
System wiring | en
51